GainOptic Group / Specifying Guide
Architectural Glass
How glass is specified.
How glass make-ups are written, and what to include in an enquiry so it can be priced in one round.
Reading a make-up
Glass is written from the outside in.
Each pane, interlayer and cavity is listed in order, separated by a plus sign.
8 T + 1.52 SGP + 8 T
8
Glass thickness in millimetres
T
Tempered (toughened)
1.52 SGP
Interlayer thickness and type
8 T
Second pane, inner side
6 Low-E T + 16 Ar + 6 T
6 Low-E T
Outer pane with Low-E coating, tempered
16
Cavity width in millimetres
Ar
Argon fill
6 T
Inner pane, tempered
What to send
A complete enquiry.
- Product and make-upWritten as above, or describe the use.
- Sizes and quantitiesWidth × height in mm and pieces per size, or a cutting list.
- Edge work and holesPolished, ground or seamed edges; hole and notch positions on a drawing.
- Coating, colour or printLow-E type, glass colour, frit pattern or artwork.
- Standard or certificationCE, AS/NZS 2208 or the project specification.
- Destination and timingDestination port and the required delivery period.
- Your company and roleProcessor, contractor, brand or distributor.
Example
An enquiry that can be priced in one round.
Project: residential tower, Dubai
Product: insulating glass for windows
Make-up: 6 mm Low-E (triple silver) T + 16 mm Ar + 6 mm clear T
Spacer: warm edge, black
Sizes: 1200 x 2400 mm - 320 pcs
1500 x 2400 mm - 180 pcs
Edges / holes: none
Standard: CE, or project specification attached
Destination: Jebel Ali, first shipment in MarchGlossary
Terms used on this site.
- T
- Tempered (toughened) safety glass.
- PVB / SGP
- Laminating interlayers. SGP is stiffer and stronger, used for balustrades, canopies and structural glass.
- 1.52
- Interlayer thickness in mm (common values 0.76 and 1.52).
- Low-E
- Low-emissivity coating that reduces heat transfer; off-line coatings come in single, double or triple silver.
- Ar
- Argon gas filled into the cavity of an insulating unit.
- 16 / 12
- Cavity width in mm between the panes of an insulating unit.
- Warm edge
- Spacer with low heat conduction, such as 4SG / TPS thermoplastic spacers.
- Surface #2
- Surfaces are counted from outside in; coatings and frit are usually on #2 or #3.
- Ceramic frit
- Ceramic ink fired into the glass during tempering.
- PDLC
- Switchable film laminated into glass that turns from clear to opaque with electricity.
Enquiries
Ready to send your specification?
Use the enquiry form or write to us directly.